16 Machine Parameters
#3132
ori_inp2
Set the in-position width when in-position advance output control (#3128/bit0) is valid. Reduce the orientation
time by setting a bigger value than the value of conventional SP024 and detecting an in-position faster.
Conventional SP024 is used for 2nd in-position signal detection width.
---Setting range---
0 to 32767 (1deg/1000)
#3133
spherr
Set the allowable angle between the commanded position and actual position of hobbing axis when it is in
tool spindle synchronization II (hobbing) mode (X18AE ON), and also when hobbing axis and workpiece axis
are synchronizing (X18A9 ON).
---Setting range---
0 to 32767 (1deg/1000)
#3134
sphtc
Set the primary delay time constant of hobbing axis automatic compensation primary delay filter control in
tool spindle synchronization II (hobbing).
When set to 0, primary delay filter control is invalid.
---Setting range---
0 to 32767 (ms)
#3135
sfwd_g
Set the feed forward gain for the hobbing axis in tool spindle synchronization II (hobbing) mode.
---Setting range---
0 to 200 (%)
#3137
stap_ax_off
Not used. Set to "0".
#3138
motor_type
Set the spindle motor type. The set type will be displayed on the drive monitor screen, and it will be also out-
put to the system configuration data.
---Setting range---
Character string within 26 characters including A-Z, a-z, 0-9, "." (decimal point), "-" (hyphen), "/" (slash)
(Cleared by inputting "0".)
(PR)
#3139
sp_srvdrv
Select whether to enable spindle control using a servo drive unit and servo motor (spindle-mode servo con-
trol).
0: Disable spindle-mode servo control
1: Enable spindle-mode servo control
(PR)
#3140
S_DINSp
Set the door signal input in the drive unit.
Use this parameter only when the axis with a door signal belongs to several door groups.
The correspondence between the door signals and bits are as follows.
bit0 : Door1 signal
bit1 : Door2 signal
If the axis does not receive any door signal, set to "0".
An error (Y20 0027) will occur in the following cases.
- Several bits are enabled.
- Any bit other than those set in "#3071 S_DSlSp" is enabled.
---Setting range---
0000 to 0002 (HEX)
2nd in-position width for orientation
Hobbing axis delay (advance) allowable angle
Primary delay time constant for hobbing axis automatic
compensation
Feed forward gain for hobbing axis
High-speed synchronous tapping disabled axis
Spindle motor type
Spindle-mode servo control
Speed observation input door No.