G140Timeout; G140Type2; Crsman; Mstsyn - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1433

G140TimeOut

Specify a period of time to wait before outputting the alarm (M01 1101) when an axis declared in the axis
exchange command is unexchangeable.
If the specified time elapses with the axis remaining unexchangeable, the alarm (M01 1101) is output.
However this alarm is cancelled and axis exchange is carried out once the axis becomes capable of being
exchanged.
0 to 254: Period of time to wait before timeout (sec)
255
: Wait until the axis becomes exchangeable without executing timeout check
(Note) This parameter is enabled when the alarm is not caused by an axis' unexchangeable state (when
#1432 Ax_Chg_Spec(bit0) = 0).
---Setting range---
0 to 254 (s)
255: No timeout
#1434

G140Type2

Select which axis address(es) can be commanded under G140 (Arbitrary axis exchange) control.
0: The axis (or axes) specified in the G140 block can be commanded.
1: Not only the axis (or axes) specified in the G140 block but those unspecified in the block can also be
commanded.
#1435

crsman

Select whether to enable manual interruption for an axis being under cross machining control.
0: Disable
1: Enable
#1436

mstsyn

Select whether to enable override for the dwell time and miscellaneous function time.
0: Disable (Override takes no effect.)
1: Enable (Override takes effect.)
#1437
SBS2_Spec
bit0: Selection of alarm when sub part system II start is disabled
Select the type of operation to be carried out when the sub part system specified by G144 is incapable of
being activated.
0: Wait until the system becomes capable of being activated
1: Output an alarm
bit1: Sub part system control II: Reset type selection
Select how to reset the sub part system control II.
0: Reset sub part system at the same time as main part system reset.
1: Not reset sub part system at the time of main part system reset.
(PR)
#1438
Ofs-SysAssign
Select the allocation method of tool offset sets.
0: Automatic equal allocation
1: Arbitrary allocation
The setting of "1" is enabled for a system configured with two or more part systems. When "1" is selected for
a system configured with a single part system, all the life management tools of the system are allocated to
the 1st part system.
(PR)
#1439
Tlife-SysAssign
Select the allocation method of the life management tools.
0: Automatic equal allocation
1: Arbitrary allocation
The setting of "1" is enabled for a system configured with two or more part systems. When "1" is selected for
a system configured with a single part system, all the life management tools of the system are allocated to
the 1st part system.
IB-1501279-H
G140 timeout period
G140 command type 2
Manual interruption during cross machining
Enable override for dwell and miscellaneous function
time
Selection of alarm when sub part system II start is dis-
abled
Enable part system allocation of tool offset sets
Part system allocation of life management tools