M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1370
S_Sig2
Set the remote I/O device to input the observation speed change signal 2 during executing the safety obser-
vation function.
When set to "0", there is no observation speed change signal input.
Therefore "X0" cannot be used as safety observation signal device.
---Setting range---
0000 to 02FF (HEX)
(PR)
#1371
PwrIntegIntvl
Specify the intervals of accumulating power consumption to create the history.
The accumulated power consumption history can be obtained according to this parameter along with "#1392
StartTimeIPC" (Power consumption accumulation start time).
When 0 is set, power consumption is not accumulated.
---Setting range---
0 to 999(hr)
#1372
DrvBasePwr
Specify the fixed power consumption of the drive system.
This value is used for calculating the power consumption.
---Setting range---
0 to 99999999(W)
(PR)
#1373
mstpssc
Enable the multi-step speed monitor.
0: Disable the multi-step speed monitor
1: Enable the multi-step speed monitor
* When enabling the multi-step speed monitor, setting values for SV238, SV239, SP238 and SP239 will be
ignored.
(PR)
#1379
S_Sig3
Set the remote I/O device to input the observation speed change signal 3 during executing the safety obser-
vation function.
When set to "0", there is no observation speed change signal input.
Therefore "X0" cannot be used as safety observation signal device.
---Setting range---
0000 to 02FF (HEX)
#1389
G1SmthChk
Select whether to apply smoothing check method to a cutting block for deceleration check, when deceleration
check method is selected individually for G0 and G1 (when "#1306 InpsTyp" = 1).
0 : Follow the setting of Aux07/BIT1
1 : Apply smoothing check method
(PR)
#1390
BackUSBUseNum
Specify the number of the display's rear USB ports occupied by a machine tool builder. Using this setting the
control determines the drive to be used for the front SD and USB memory.
(Note) This parameter is enabled for a Windows-based display of M800W/M80W.
---Setting range---
0 to 6
(PR)
#1391
User level protect
Enable the function of Data protection by user's level.
0: Use a machine user password to switch the protection of each operation (same as the conventional
models)
1: Switch the protection according to the protective levels (0 to 7) specified for each operation through the
protection setting screen
(Note) You are authorized to change this parameter from 1 to 0 only if your operation level is the same or
higher than that of "Available level" on the protection setting screen.
Safety observation signal device 2
Power consumption accumulation interval
Fixed drive system power consumption
Multi-step speed monitor enabled
Safety observation signal device 3
Smoothing check method in cutting block
Number of backside USB ports occupied
Enable Data protection by user's level