M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#2641

m_clamp

Specify the maximum speed to be applied to each axis when manual speed clamp is enabled.
When 0 is set, the rapid traverse rate (#2001 rapid) is applied.
---Setting range---
0 to 1000000(mm/min)
#2642

jogfeed

Specify a feed rate to be applied to each axis during jog mode.
When 0 is set, the manual feed rate selected by Manual feedrate method selection (JVS) signal is applied.
---Setting range---
0 to 1000000(mm/min)
(PR)
#2643

LdMeter thresholdY

Specify the servo load current (%) at which the loadmeter displays a caution sign (yellow).
If servo load current exceeds the specified value, the loadmeter displays a caution (yellow).
If you wish to avoid showing the caution (yellow), set this parameter to be the same as "#2644 LdMeter
thresholdR".
When "0" is set, the value becomes 100% (default).
---Setting range---
0 to 300 (%)
(PR)
#2644
LdMeter thresholdR
Specify the servo load current (%) at which the loadmeter displays a warning sign (red).
If servo load current exceeds the specified value, the loadmeter displays a warning (red).
If you wish to avoid showing the warning (red), set this parameter to be the same as "#2645 LdMeter load
max".
When "0" is set, the value becomes 150% (default).
---Setting range---
0 to 300 (%)
(PR)
#2645

LdMeter load max

Specify the maximum servo load current (%) for loadmeter display.
When "0" is set, the value becomes 200% (default).
---Setting range---
0 to 300 (%)
#2646
distt
Set the responsiveness of the process which detects the disturbance torque.
---Setting range---
0 to 1000 (ms) (Default value: 0)
(PR)
#2651
RT2G0
Select whether to enable switching of G0 acceleration/deceleration time constant.
0: Disable switching of G0 acceleration/deceleration time constant.
1: Enable switching of G0 acceleration/deceleration time constant.
(PR)
#2652
RT2G1
Select whether to enable switching of G1 acceleration/deceleration time constant.
0: Disable switching of G1 acceleration/deceleration time constant.
1: Enable switching of G1 acceleration/deceleration time constant.
IB-1501279-H
Manual feed clamp speed
Jog feed rate
Loadmeter: Caution (Yellow) threshold
Loadmeter: Warning (Red) threshold
Loadmeter: Maximum servo load current
Load observation disturbance torque filter time con-
stant
RT2: Minimum value of G0 acce/dece time constant
RT2: Enable switching of G1 acce/dece time constant