M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1228
aux12
bit0:
When not using, set to "0".
bit1: Switch "offset and parameter" screen
Select to switch the "offset and parameter" screen to the parameter screen.
0: Display the "offset and parameter" screen.
1: Display the "parameter" screen.
bit2: Switch data protection in data transmission mode
[M8]
Select the range of data protection in data transmission mode.
0: Enable the protection for both send and receive data.
1: Enable the protection for receive data only.
[C80]
Not used.
bit3: Nose R specification
Select whether to specify the nose R compensation by shape or wear number.
0: Specifies the nose R compensation by shape number.
1: Specifies the nose R compensation by wear number.
bit4: Select operation error or stop code
Select operation error or stop code to provide for both block start and cutting start interlocks.
0: Operation error
1: Stop code
bit5: Select constant surface speed coordinates
Select the constant surface speed coordinate.
0: Workpiece coordinate
1: Absolute value coordinate
bit6: Switch relative values displayed
Select whether to preset the relative coordinates with workpiece coordinate preset (G92.1) or counter preset
(G92).
0: Preset the relative coordinates.
1: Not preset the relative coordinates.
bit7: Protection with manual value command
Select whether to protect a manual value command.
0: Not protect. (Conventional specification)
1: Protect.
395
IB-1501279-H