#1145
I_abs
Select how to handle the absolute position data during automatic handle interrupt.
0: Absolute position data will be renewed if manual ABS switch is ON. If it is OFF, data won't be renewed.
1: Follow the "intabs" state when "#1061 intabs" is enabled
#1146
Sclamp
Select how to handle the spindle rotation speed clamp function with the G92/G50S command.
0: G92/G50S command is handled as a clamp command only in the G96 state (during constant surface
speed control).
G92S will be handled as normal S command in G97 state (constant surface speed OFF).
1: The S command in the same block as G92/G50 is constantly handled as a clamp command
#1147
smin_V
Specify the type of spindle min. rotation speed clamp value.
0: Rotation speed setting
1: Output voltage coefficient setting
Set "#3023 smini" according to this type setting.
#1149
cireft
Select whether to decelerate at the arc entrance or exit.
0: Not decelerate
1: Decelerate
#1153
FixbDc
Select whether to perform a deceleration check or in-position check at the hole bottom in a hole drilling cycle.
This parameter is enabled only for a hole drilling cycle in which no dwell command can be issued at the hole
bottom.
0: Perform no deceleration check and in-position check
1: Perform deceleration check
2: Perform in-position check
(PR)
#1154
pdoor
Not used. Set to "0".
#1155
DOOR_m
Not used. Set to "100".
#1156
DOOR_s
Not used. Set to "100".
#1157
F0atrn
Not used. Set to "0".
#1158
F0atno
Not used. Set to "0".
(PR)
#1163
No rio
Select whether to enable or disable RIO connection detection.
0: Enable
1: Disable
If your I/O consists of only cards such as CC-LINK, setting this parameter to "1" will avoid the RIO commu-
nication cutoff alarm.
(PR)
#1164
ATS
Select whether to enable or disable the automatic tuning function.
0: Disable
1: Enable
(Note) Enable this parameter when using MS Configurator.
Manual ABS parameter
Spindle rotation speed clamp function
Minimum spindle rotation speed clamp type
Arc deceleration speed change
Hole bottom deceleration check
RIO connection detection invalid
Automatic tuning function