M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#3128
ori_spec
bit1: High-speed proximity-switch orientation
[M8]
Select whether to enable high-speed proximity-switch orientation.
This orientation can be used when Proximity-switch spindle zero point detection (#3106 zrn_typ/bitF) is en-
abled.
0: Disable
1: Enable
[C80]
Not used.
bit0: Orientation in-position advance output
Reduce the orientation time by detecting an in-position faster.
The in-position detection width is changed from SP024(#13024) to ori_inp2.
0: Invalid
1: Valid
---Setting range---
0x0000 to 0xffff (hexadecimal)
Orientation control specification
563