16 Machine Parameters
#1210

RstGmd

Select whether to initialize G code group modals and H and D codes, which corresponds to bits as follows,
when the system is reset.
0: Initialize.
1: Not initialize.
<Description of bits for M system>
1F 1E 1D 1C
0 0 0 0
F
E D C
0 *
*
*
bit 1F: (Not used)
bit 1E: (Not used)
bit 1D: (Not used)
bit 1C: (Not used)
bit 1B: (Not used)
bit 1A: (Not used)
bit 19: Spindle clamp rotation speed initialization
bit 18: H, D codes initialization
bit 17: (Not used)
bit 16: (Not used)
bit 15: (Not used)
bit 14: (Not used)
bit 13: Group 20 2nd spindle control modal initialization
bit 12: Group 19 G command mirror modal initialization
bit 11: Group 18 Polar coordinate command modal initialization
bit 10: Group 17 Constant surface speed control command modal initialization
bit F: Group 16 Retains inclined surface machining modal
bit E: Group 15 Normal line control modal initialization
bit D: (Not used)
bit C: Group 13 Cutting modal initialization
bit B: Group 12 Workpiece coordinate system modal initialization
bit A: (Not used)
bit 9: Group 10 Fixed cycle return command modal initialization
bit 8: (Not used)
bit 7: Group 8 Length compensation modal initialization
bit 6: Group 7 Radius compensation modal initialization
bit 5: Group 6 Inch/metric modal initialization
bit 4: Group 5 Feed G modal initialization
bit 3: (Not used)
bit 2: Group 3 Absolute/incremental command modal initialization
bit 1: Group 2 Plane selection modal initialization
bit 0: Group 1 Move G modal initialization
IB-1501279-H
1B 1A 19 18
17 16 15 14
13 12 11 10
0 0 *
0 0 0 0
*
*
B A
9
8
7
6
5
4
3
0 *
0
0 *
*
*
*
*
*
354
Modal G code reset
*
*
*