M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1254
set26
bit0: Reducing processing time of zero-travel-distance block (for L system only)
Select whether to reduce the processing time of a zero-travel-distance block.
0: Disable the reduction of non-travel block processing time.
1: Enable the reduction of non-travel block processing time.
bit1: Program format switch
[M8]
Enable the program format switch function.
0: Disable the function
1: Enable the function
[C80]
Not used.
bit3: Select timing for updating axis parameter
Select the timing for when to update axis parameter.
0: Update after All axes smoothing zero turns ON for all the part systems.
1: Update after All axes smoothing zero turns ON for each part system.
bit4: Reference of zero point shift distance for spindle C axis
[M8]
Select the reference method for zero point shift distance when C axis returns to zero under spindle C axis
control.
0: Use "#2027 G28sft" as the zero point shift distance.
1: Use "#3113 cax_sft" as the zero point shift distance.
[C80]
Not used.
IB-1501279-H