#3194
LdMeter load max
Specify the maximum spindle load (%) for loadmeter display.
When "0" is set, the value becomes 200% (default).
---Setting range---
0 to 300 (%)
(PR)
#3195
mgrsptyp
Spindle's machine group setting type
Specify which of the spindle's machine group No. parameters to use for the machine groupwise alarm stop
function.
0: #3196 mgrspnum1 (Spindle's machine group No. 1)
1: #3197 mgrspnum2 (Spindle's machine group No. 2)
---Setting range---
0/1
(PR)
#3196
mgrspnum1
Spindle's machine group No. 1
Specify the machine group No. to which each spindle belongs.
This parameter is enabled when the parameter "#3195mgrsptyp (Spindle's machine group setting type)" is
set to 0.
---Setting range---
0 to 32
(PR)
#3197
mgrspnum2
Spindle's machine group No. 2
Specify the machine group No. to which each spindle belongs, by setting the corresponding bit.
This parameter is enabled when the parameter "#3195mgrsptyp (Spindle's machine group setting type)" is
set to 1.
---Setting range---
00 to FF
Set this in hexadecimal format.
#13501
vfths11
Set the spindle speed for changing the 1st step's acceleration/deceleration time constant at gear 00.
---Setting range---
0 to 99999(r/min)
#13502
vfths12
Set the spindle speed for changing the 1st step's acceleration/deceleration time constant at gear 01.
---Setting range---
0 to 99999(r/min)
#13503
vfths13
Set the spindle speed for changing the 1st step's acceleration/deceleration time constant at gear 10.
---Setting range---
0 to 99999(r/min)
#13504
vfths14
Set the spindle speed for changing the 1st step's acceleration/deceleration time constant at gear 11.
---Setting range---
0 to 99999(r/min)
Loadmeter: Maximum spindle load
Spindle's machine group setting type
Spindle's machine group No. 1
Spindle's machine group No. 2
Variable speed thread multi-step accel/decel change-
over speed 1 (Gear00)
Variable speed thread multi-step accel/decel change-
over speed 1 (Gear01)
Variable speed thread multi-step accel/decel change-
over speed 1 (Gear10)
Variable speed thread multi-step accel/decel change-
over speed 1 (Gear11)