M800/M80/E80/C80 Series Alarm/Parameter Manual
5 System Alarms (Z)
Z29
EtherNet/IP communication err
Details
A communication error has occurred in the communication that uses an EtherNet/IP expansion unit.
[n1: Output the device Number (in hexadecimal format)]
FF: Simultaneously mounting two EtherNet/IP expansion units error
Other than FF: Device No. of the connected device
[n2: Output the position No. (in hexadecimal format)]
FF: Simultaneously mounting two EtherNet/IP expansion units error
Other than FF: Device No. of the connected device
[n3: Output the device communication status (IN) (in hexadecimal format)]
[n4: Output the device communication status (OUT) (in hexadecimal format)]
For details, refer to "EtherNet/IP Specifications manual".
Z31
Socket open error(socket)
Details
Socket open error (socket)
Remedy
Set the parameter then turn the power OFF and ON again.
Z31
Socket bind error(bind)
Details
Socket bind error (bind)
Remedy
Set the parameter then turn the power OFF and ON again.
Z31
Connection wait queue error(listen)
Details
Connection wait queue error (listen)
Remedy
Set the parameter then turn the power OFF and ON again.
Z31
Connection request error(accept)
Details
Connection request error (accept)
Z31
Data recv error(socket error)
Details
Data receive error (socket error)
Z31
Data recv error(data error)
Details
Data receive error (data error)
Z31
Data send error(socket error)
Details
Data send error (socket error)
Z31
Data send error(data error)
Details
Data send error (data error)
Z31
Socket close error(close)
Details
Socket close error (close)
Remedy
Set the parameter then turn the power OFF and ON again.
IB-1501279-H
n1 n2 n3 n4
0001
0002
0003
0004
0005
0006
0007
0008
000A
84