Mitsubishi Electric M800 Series Manual page 601

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#43080
GRB1ex
[M8]
Specify the number of motor-side gear teeth for "Gear selection command (Control input 4/bit6, 5) = 00".
When 0 is set, extended gear ratio is disabled.
When not using extended gear ratio, set 0.
---Setting range---
0 to 2147483647
(PR)
#43081
GRB2ex
[M8]
Specify the number of motor-side gear teeth for "Gear selection command (Control input 4/bit6, 5) = 01".
When 0 is set, extended gear ratio is disabled.
When not using extended gear ratio, set 0.
---Setting range---
0 to 2147483647
(PR)
#43082
GRB3ex
[M8]
Specify the number of motor-side gear teeth for "Gear selection command (Control input 4/bit6, 5) = 10".
When 0 is set, extended gear ratio is disabled.
When not using extended gear ratio, set 0.
---Setting range---
0 to 2147483647
(PR)
#43083
GRB4ex
[M8]
Specify the number of motor-side gear teeth for "Gear selection command (Control input 4/bit6, 5) = 11".
When 0 is set, extended gear ratio is disabled.
When not using extended gear ratio, set 0.
---Setting range---
0 to 2147483647
#43084
protect_sp_st_tmp
[M8]
Specify the motor temperature at which spindle protection starts.
When the spindle motor temperature reaches the set temperature or higher, the acceleration/deceleration
time constant is switched from that of S command to that for spindle protection.
Set a temperature that is the same as or higher than the spindle protection cancel temperature.
When 0 is set, the spindle acceleration/deceleration time constant is not switched according to the tempera-
ture.
---Setting range---
0 to 200 (°C)
#43085
protect_sp_rls_tmp
[M8]
Specify the motor temperature at which spindle protection is cancelled.
When the spindle motor temperature drops below the set temperature, the acceleration/deceleration time
constant is switched from that for spindle protection to that of S command.
Set a temperature that is the same as or lower than the spindle protection start temperature.
When the set temperature is 0 or higher than the spindle protection start temperature, the cancel temperature
is set 10 degrees lower than the start temperature.
---Setting range---
0 to 200 (°C)
IB-1501279-H
Motor-side extended gear ratio 1
Motor-side extended gear ratio 2
Motor-side extended gear ratio 3
Motor-side extended gear ratio 4
Spindle protection start temperature
Spindle protection cancel temperature
584

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents