M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#8711

TLM L meas axis

Set the tool length measurement axis.
Set the "#1022 axname2" axis name.
---Setting range---
Axis name
(Note) If the axis name is illegal or not set, the 3rd axis name will be set as default.
#8712

TLM D meas axis

Set the tool diameter measurement axis.
Set the "#1022 axname2" axis name.
---Setting range---
Axis name
(Note) If the axis name is illegal or not set, the 1st axis name will be set as default.
#8713

Skip coord. Switch (For M system only)

Select the coordinate system for reading skip coordinate value.
Select whether to read the skip coordinate in the workpiece coordinate system or in the feature coordinate
system during inclined surface machining command.
Select whether to read the skip coordinate in the workpiece coordinate system or in the workpiece installation
coordinate system during workpiece installation error compensation.
0: Workpiece coordinate system
1: Feature coordinate system/Workpiece installation coordinate system
#8714

Thrdrecut lead ax

Specify the name of lead axis that performs thread recutting.
If any nonexistent axis name is specified, the 1st axis of the part system is used as a lead axis for thread
recutting.
If the parameter "#8714 Thrdrecut lead ax" is unspecified, Z axis is set as the parameter value at power ON.
---Setting range---
A,B,C,U,V,W,X,Y,Z
#8715
Thread recut SP#
Specify the No. or name of spindle that performs thread recutting.
If 0 or any nonexistent spindle No. or name is specified, the 1st spindle is used for thread recutting.
---Setting range---
Spindle No. method: 0 to 8
Spindle name method: 0 to 9
(Default: 0)
(PR)
#8716
EXT/Wrksft Share (for L system only)
Set this parameter to "1" if you wish to disable the external workpiece coordinate system offset.
This parameter is enabled when "#11056 Workshift invalid (worksft invalid)" is "0".
0: Use the external work coordinate offset (EXT) to implement compensation
1: Implement compensation without using the external work coordinate offset (EXT)
#8717
WE measure wk zero
[M8]
Specify the workpiece zero position that is used for measuring the workpiece installation error.
0: Workpiece center
1: Apex in X-, Y- direction
2: Apex in X+, Y- direction
3: Apex in X+, Y+ direction
4: Apex in X-, Y+ direction