Memval; Radius; Decpt2; F1Digt - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1052

MemVal

0: Common variables common for part systems (number fixed)
#100 - : Per part system
#500 - : Common for part systems
1: Common variables common for part systems (number designation)
#100 - : Designate with V1comN
#500 - : Designate with V0comN
(Note 1) When this parameter is changed, the file system will be changed after the power is turned ON.
So always execute format.
The new format will be enabled after turning the power ON again.
Setting order
(1) MemVal changeover -> (2) Turn power ON again -> (3) Format -> (4) Turn power ON again
(Note 2) When this parameter is set to "1", #900000 to #907399 are not available even if the number of com-
mon variables is 8000.
#1077

radius

Select whether the incremental command of the diameter specification axis ("#1019 dia" is set to "1") uses
the diameter value or radius value.
0: Diameter value
1: Radius value
#1078

Decpt2

Select the increment of position commands that do not have a decimal point.
0: Minimum input command unit (follows "#1015 cunit")
1: 1mm (or 1inch) unit (For the dwell time, 1s unit is used.)
#1079

F1digt

Select the F command method.
0: Direct numerical command (command feedrate during feed per minute or rotation)
1: 1-digit code command (feedrate set with "#1185 spd_F1" to "#1189 spd_F5")
#1080
Dril_Z
Select a fixed cycle hole drilling axis.
0: Use an axis vertical to the selected plane as hole drilling axis.
1: Use the Z axis as the hole drilling axis regardless of the selected plane.
#1081
Gmac_P
Select the G code priority relationship during the macro call with G command.
0: Priority is on G code used in the system
1: Priority is on registered G code for call
#1082
Geomet
Select the type of geometric to use.
0: Not use
1: Use only geometric I
2: Use geometric I and IB
With geometric, specific address codes are used for exclusive meanings. Thus, if A or C is used for the axis
name or 2nd miscellaneous command code, the A used for the axis name may function as the geometric's
angle designation. Pay special attention to axis names, etc., when using this function.
#1084
RadErr
Set the tolerable error range when the end point deviates from the center coordinate in the circular command.
---Setting range---
0 to 1.000 (mm)
No. of common variables shared in part system desig-
nation
Incremental command for diameter specification axis
Decimal point type 2
Validate F1 digit
Drilling Z fixed
Give priority to G code parameter
Geometric
Arc error
381
IB-1501279-H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents