M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1326
PLC Const Ext. Num
Set the number of PLC constant extension points.
---Setting range---
0 to 750
#1327
3D ATC type
Select the tool change method for determining the tool to draw solids.
With 3D drawing, the tool will be changed by the method designated with this parameter, and then the image
will be drawn.
0: With one standby tool
1: With two standby tools
2: With no standby tool
#1328
TLM type
Select the tool measurement method.
0: Use the machine position at TLM switch ON as 0.
1: Use the machine zero point as standard.
#1329
Emgcnt
Set the time taken for the drive section's main power to be shut-off when the confirmation of all the axes' stop
failed after the emergency stop state.
The contactor shut-off signal is output as soon as all the axes are confirmed stopped if the confirmation is
done prior to the set time.
When there is no safety observation option or "0" is set, the shut-off time will be 30(s).
---Setting range---
0 to 60 (s)
(PR)
#1330
MC_dp1
When safety observation is executed, set the remote I/O device to input the contactor's auxiliary b contact
signal used for the contactor weld detection.
If "0" is set, weld detection will not be executed.
Thus, "X0" cannot be used as contactor weld detection device.
---Setting range---
[M8]
0000 to 02FF (HEX)
[C80]
0000 to 01FF (HEX)
(PR)
#1331
MC_dp2
When safety observation is executed, set the remote I/O device to input the contactor's auxiliary b contact
signal used for the contactor weld detection.
If "0" is set, weld detection will not be executed.
Thus, "X0" cannot be used as contactor weld detection device.
---Setting range---
[M8]
0000 to 02FF (HEX)
[C80]
0000 to 01FF (HEX)
PLC constant extension number
Tool change method specification
Tool measurement standard positions election
Emergency stop contactor shut-off time
Contactor weld detection device 1
Contactor weld detection device 2