M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1425
M_wait[M479-448]
Register an M code that needs special operation.
Each bit of the set value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
Note that operation of the registered M code varies according to #1401 M_mode.
---Setting range---
0 to FFFFFFFF
Set this in hexadecimal format.
#1426
M_wait[M511-480]
Register an M code that needs special operation.
Each bit of the set value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
Note that operation of the registered M code varies according to #1401 M_mode.
---Setting range---
0 to FFFFFFFF
Set this in hexadecimal format.
(PR)
#1427
RT2AftG1
Select whether to enable switching of acceleration/deceleration time constant after G1 interpolation.
0: Disable switching of acceleration/deceleration time constant after G1 interpolation.
1: Enable switching of acceleration/deceleration time constant after G1 interpolation.
(PR)
#1428
RT2rst
Select whether to change acceleration/deceleration time constant back to parameter value when NC is reset.
0: Disable changing acceleration/deceleration time constant back when NC is reset.
1: Enable changing acceleration/deceleration time constant back when NC is reset.
(PR)
#1431
Ax_Chg
Choose which of the following controls to enable:
Mixed control I or II or Arbitrary axis exchange control.
0: Mixed control I or II
1: Arbitrary axis exchange control
#1432
Ax_Chg_Spec
bit0: Selection of alarm when axis exchange is disabled
Select whether to issue an alarm or wait until the axis becomes exchangeable when axis exchange is dis-
abled.
0: Wait until the axis becomes exchangeable when the axis declared in an axis exchange command is
incapable of being exchanged.
* The parameter #1433 (G140TimeOut) determines the operation to be carried out during the waiting
time.
1: Output the alarm (M01 1101) when the axis declared in an axis exchange command is incapable of be-
ing exchanged.
bit1: Compensation cancel after arbitrary axis exchange
Select whether to enable canceling of compensation after an arbitrary axis exchange.
0: Not cancel compensation after arbitrary axis exchange
1: Cancel compensation after arbitrary axis exchange
Special operation registration M code
Special operation registration M code
RT2: Enable switching of acce/dece time constant after
G1 interpolation
RT2: Enable changing acce/dece time constant back
when NC is reset
Selection of mixed control or arbitrary axis exchange
control
445