#1188
spd_F4
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F4 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be increased/de-
creased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
#1189
spd_F5
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F5 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be increased/de-
creased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
(PR)
#1190
s_xcnt
Select whether to enable or disable inclined axis control.
0: Disable inclined axis control
1: Enable inclined axis control
(PR)
#1191
s_angl
Set the inclination angle (θ).
(Note) When set to "0", the angle determined by three-side setting will be applied.
---Setting range---
-80.000 to 80.000 (°)
(PR)
#1192
s_zrmv
Select whether to perform compensation for the base axis corresponding to the inclined axis at reference
position return.
0: Perform compensation
1: Not perform compensation
#1193
inpos
The setting is selected with the parameter "#1306 InpsTyp".
0: Deceleration check method 1
Select the deceleration check method for G0.
0: Command deceleration check
1: In-position check
2: Smoothing check
1: Validate in-position check
0: G0, G1+G9 Command deceleration check
1: G0, G1+G9 In-position check
2: G0, G1+G9 Smoothing check
#1194
H_acdc
Select the time constant for manual handle feed.
0: Use time constant for G01
1: Time constant 0 (step)
F1 digit feedrate F4
F1 digit feedrate F5
Validate inclined axis control (for L system only)
Inclination angle (for L system only)
Compensation at reference position return (for L sys-
tem only)
Deceleration check method 1
Time constant 0 for handle feed