M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1293
ext29
bit0: Synchronous feed in milling
Select whether to enable synchronous feed in milling interpolation, cylindrical interpolation or polar coordi-
nate interpolation mode.
0: Disable
1: Enable
bit1: Enabling N0 command
Select how to handle a command of sequence number zero (N0).
0: N0 causes an error.
1: N0 is ignored (causes no error).
(PR)
#1294
ext30
Not used. Set to "0".
(PR)
#1295
ext31
bit6: Analog spindle synchronous tapping ON
[M8]
Select whether to enable analog spindle synchronous tapping.
0: Disable
1: Enable
(PR)
#1296
ext32
Not used. Set to "0".
(PR)
#1297
ext33
Not used. Set to "0".
(PR)
#1298
ext34
Not used. Set to "0".
(PR)
#1299
ext35
Not used. Set to "0".