M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P657
PLC Device too much
Details
Multiple assignment expressions which include the PLC direct interface command are commanded to the same
block.
Remedy
Command the assignment command using PLC direct interface by itself.
P700
Illegal command value
Details
Spindle synchronization was commanded to a spindle that is not connected serially.
Remedy
Correct the program.
Correct the parameter settings.
P705
Dia/Rad selection cmd invalid
Details
G10.9 was commanded during a modal in which diameter/radius designation selection is not available.
Remedy
Check the program.
P706
Invld cmd in dia/rad selection
Details
A G code impossible to command was issued during switching between diameter and radius using the diame-
ter/radius designation selection.
Remedy
Check the program.
P801
Turning tool offset disabled
Details
Any of the following commands has been given during the G43.7 mode.
Mirror image by G code
Mirror image by parameter setting
Mirror image by external input
Tool length compensation along the tool axis
Automatic tool length measurement
A G43.7 command has been given in any of the following modes.
Mirror image by G code
Mirror image by parameter setting
Mirror image by external input
Fixed cycle for drilling
Remedy
Check the program. If you use the mirror image, tool length compensation along the tool axis, automatic
tool length measurement or fixed cycle for drilling, use a G49 command to cancel the tool position offset.
P802
Nose R compensation disabled
Details
Any of the following commands has been given during nose R compensation for machining center system.
Mirror image by G code
Mirror image by parameter setting
Mirror image by external input
Nose R compensation for machining center system has been executed in any of the following modes.
Mirror image by G code
Mirror image by parameter setting
Mirror image by external input
Remedy
Check the program. If you use the mirror image, use a G40 command to cancel the nose R compensation
for machining center system.
155