Smart Safety Observation Error (V01/V02/V03/V04/V05/V06/V07); Safety Watchdog Error; Cross-Check Error; Safe Sys Internal Process Err - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
13 Smart Safety Observation Alarm (V)
13Smart Safety Observation Alarm (V)

13.1 Smart Safety Observation Error (V01/V02/V03/V04/V05/V06/V07)

V01

Safety watchdog error

Details
Safety function is not carried out in specified cycle.
Remedy
CPU may be faulty. Contact our service center.
V01

Cross-check error

Details
Each operation result of redundant CPU is different value.
Remedy
CPU may be faulty. Contact our service center.
V01

Safe sys internal process err

Details
An error has occurred in the NC's internal process during execution of a safety function.
The screen displays which safety function has been executed at the time of error, using the following numbers.
0001: Safely-limited speed (SLS)
0002: Safely-limited position (SLP)
0003: Safe speed monitor (SSM)
0004: Safe cam (SCA)
0005: Safe operating stop (SOS)
0006: Safe stop 1 (SS1)
0007: Safe stop 2 (SS2)
0008: Safe torque off (STO)
0009: Safe brake control (SBC)
000A: Diagnostic function
000B: Safety I/O-related observation
Remedy
CPU may be faulty. Contact our service center.
V01
Safe para storage memory err 1
Details
Safety parameter (for internal processing) which is saved in the memory is illegal value.
Remedy
Input Safety parameter file and turn power ON again.
Clear the memory. (All data on the memory will be initialized. Back up the data as needed.)
When the above action does not help restoring, memory may be faulty. Contact our service center.
V01
Safe para storage memory err 2
Details
Safety parameter which is saved in the memory is illegal value.
Remedy
Input Safety parameter file and turn power ON again.
Clear the memory. (All data on the memory will be initialized. Back up the data as needed.)
When the above action does not help restoring, memory may be faulty. Contact our service center.
V01
Safety initial process timeout
Details
The initialization process of the safety function at power ON is not completed within specified time.
Remedy
CPU may be faulty. Contact our service center.