M800/M80/E80/C80 Series Alarm/Parameter Manual
11 Network Service Errors (N)
11Network Service Errors (N)
N001
Modem initial error
Details
An error occurred in the modem connection at the power ON.
Remedy
Check the connection between the NC and modem, connection port and power supply to modem.
N002
Redial over
Details
The number of redials exceeded due to the dial transmission failure.
Remedy
Wait a while, and then dial again.
N003
TEL unconnect
Details
The phone line is not connected.
Remedy
Check for any disconnection in the modem's phone line.
N004
Net communication error
Details
An error other than the above occurred during communication.
Remedy
Note down how the error occurred and contact the service center.
N005
Invalid net communication
Details
The modem connection port is being used for another function such as input/output.
The modem connection port settings are incorrect.
Remedy
Stop using the modem connection port with the other function, and then turn the power ON again.
Correct the settings of the modem connection port.
N006
Received result of diagnosis
Details
A diagnosis data file has been received.
Remedy
Clear the message.
N007
Send data size over
Details
A file larger than Anshin-net server capacity (64Kbyte) has been transmitted in machining data sharing.
Remedy
Reduce the size of machining program file so that it won't exceed the capacity of Anshin-net server.
N008
No file on server
Details
The file reception failed in machining data sharing because no file exists on Anshin-net server.
Remedy
Confirm that a machining program file exists on Anshin-net server before receiving it.
IB-1501279-H
120