16 Machine Parameters

16.33.3 CC Link IE Field Master Parameters

#83400+10(n-1)
Specify the station No. of slave station connected to the network. (n=1 to 64)
There is no need to number the stations sequentially. (duplication is not acceptable)
---Setting range---
0 to 64
0: No setting
#83401+10(n-1)
Specify the station type for slave stations. (n=1 to 64)
Set the same station type as that of the units that are actually connected to the network.
---Setting range---
0: No setting
1: Remote I/O station
2: Remote device station
3: Intelligent device station
4: Local station
#83402+10(n-1)
Specify the number of RX/RY link devices that perform link refresh with slave stations. (n=1 to 64)
Set the number in increments of 16.
---Setting range---
Local or intelligent device station: 0 to 2048
Remote device station: 0 to 128
Remote I/O station: 0 to 64
#83403+10(n-1)
Specify the start device No. of RX/RY link devices that perform link refresh with slave stations. (n=1 to 64)
Set the number in increments of 16.
---Setting range---
0 to 3FF0 (hexadecimal)
#83404+10(n-1)
Specify the number of RWr/RWw link devices that perform link refresh with slave stations. (n=1 to 64)
Set the number in increments of 4.
---Setting range---
Local or intelligent device station: 0 to 1024
Remote device station: 0 to 64
Remote I/O station: Setting is disabled (fixed to 0)
#83405+10(n-1)
Specify the start device No. of RWr/RWw link devices that perform link refresh with slave stations. (n=1 to 64)
Set the number in increments of 4.
---Setting range---
0 to 1FFC (hexadecimal)
#83406+10(n-1)
Designate the station as reserved station or error invalid station. (n=1 to 64)
---Setting range---
0: No setting
1: Reserved station
2: Error invalid station
IB-1501279-H
CN01 Station No.
CN01 Station Type
CN01 RX/RY size
CN01 RX/RY DNo.
CN01 RWr/RWw size
CN01 RWr/RWw DNo.
CN01 Set rsvd sts
722
Station No. (slave station)
Station type (slave station)
Number of RX/RY link devices
Start device No. of RX/RY link devices
Number of RWr/RWw link devices
Start device No. of RWr/RWw link devices
Reserved/Error invalid station setting