Mitsubishi Electric M800 Series Manual page 693

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#12815+10(n-1)
Set the excessive error detection width when "operation parameter group n" is selected.
The excessive error alarm (S03 0052) will be detected when the position droop becomes larger than this set-
ting value.
In the stopper positioning operation mode, this will be regarded as excessive error detection width when po-
sitioning to the stopper starting coordinates. .
---Setting range---
0 to 32767( ° or mm)
#12816+10(n-1)
Set the tolerable value at which "set position reached" (JST) or "automatic set position reached" (JSTA) sig-
nal is output when "operation parameter group n" is selected.
"Set position reached" (JST) indicates that the machine position is at any station.
During automatic operation, "automatic set position reached" (JSTA) is also output under the same condition.
These signals will turn OFF when the machine position moves away from the station over this value.
---Setting range---
0.000 to 99999.999( ° or mm)
#12817+10(n-1)
Set the tolerable value at which "near set position" (NEAR) signal is output when "operation parameter group
n" is selected.
"Near set position" (NEAR) indicates that the machine position is near any station position.
This value is generally set wider than the set position output width. During operations, this is related to the
special commands when the station selection is set to "0".
---Setting range---
0.000 to 99999.999(° or mm)
(PR)
#12818+10(n-1)
Select the acceleration/deceleration type when "operation parameter group n" is selected.
0, 1: Linear acceleration/deceleration
F: S-pattern acceleration/deceleration
#12850
aux_stpos2
Set the station 2 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12851
aux_stpos3
Set the station 3 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12852
aux_stpos4
Set the station 4 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12853
aux_stpos5
Set the station 5 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
IB-1501279-H
aux_ODn
aux_justn
aux_nearn
aux_smgstn
676
Operation parameter group n Excessive error detection
width
Operation parameter group n Set position output width
Operation parameter group n Near set position output
width
Operation parameter group n Acceleration/Deceleration
type
Station 2 coordinate
Station 3 coordinate
Station 4 coordinate
Station 5 coordinate

Hide quick links: