#3023
smini
Set the minimum spindle speed.
If an S command below this setting is issued, the spindle will rotate at the minimum speed set by this param-
eter.
---Setting range---
0 to 32767 (r/min)
(PR)
#3024
sout
Select the connection method with a spindle drive unit.
0: No unit to connect
1: Optical digital communication (Mitsubishi spindle drive unit)
2 - 5: S-analog (Analog spindle drive unit)
---Setting range---
0 to 5
(PR)
#3025
enc-on
Set the connection specifications of a spindle's encoder.
0: Without encoder feedback when using analog spindle and connecting to NC
1: With encoder feedback when using analog spindle and connecting to NC
2: Mitsubishi spindle drive unit
---Setting range---
0 to 2
#3026
cs_ori
Select the coil control in orientation mode for the spindle motor which performs coil changeover.
0: Perform coil changeover based on the command from NC. (depending on the setting of parameter
#1239/bit0)
1: Use the coil L
#3027
cs_syn
Select the coil control in spindle synchronization control mode for the spindle motor which performs coil
changeover.
0: Perform coil changeover based on the command from NC. (depending on the setting of parameter
#1239/bit0)
1: Use the coil H
#3028
sprcmm
Set the M codes for the spindle forward run/reverse run commands during tapping cycle.
High-order 3 digits: Set the M code for spindle forward run command.
Low-order 3 digits: Set the M code for spindle reverse run command.
When "0" is set, it is handled assuming that "3004" is set (the M code for spindle forward run command is "3"
and the M code for spindle reverse run command is "4").
---Setting range---
0 to 999999
#3029
tapsel
Select the speed which is compared with S command at gear selection when using asynchronous tapping
control with the spindle which performs gear changeover.
0: Synchronous tapping 1st step rotation speed (stap)--- Multi-step acceleration/deceleration is not used.
1: Maximum speed (smax)--- Multi-step acceleration/deceleration is used.
This parameter is enabled only when "#1272 ext08/bit1 is 1".
#3030
Not used. Set to "0".
IB-1501279-H
Minimum rotation speed
Spindle connection
Spindle encoder
Selection of winding in orientation mode
Selection of winding in spindle synchronization control
mode
Tap cycle M command selection
Asynchronous tap gear selection