M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters

15.13 Operation Parameters

#8901

Counter type 1

Select the type of the following counters on the Monitor screen.
Normal display: Upper-left counter
2-, 3- or 4-part system simultaneous display (four counters): Upper-left counter
2-, 3- or 4-part system simultaneous display (two counters): Upper counter
2-, 3- or 4-part system simultaneous display (one counter): Counter
Either relative position or tip work position is displayed by default.
(Note 1) [M8] 3- or 4-part system simultaneous display is enabled for a 15- or 19-type display unit only.
[C80] 3- or 4-part system simultaneous display is not available.
(Note 2) Tip work position is displayed when 5-axis-related option is ON.
(Note 3) PLC axis position is displayed when "#11091 PLC counter valid" is "1". [M8]
1: Current position
2: Workpiece coordinate position
3: Machine position
4: Program position
8: Remain command
9: Manual interrupt amount
10: Next command
11: Restart position
12: Remain distance
16: Tip workpiece coordinate position
18: Tool axis movement
19: Tip machine position
20: Relative position
21: Table coordinate position
22: Workpiece installation position
23: Inclined surface coordinate position
[M8]
27: PLC axis position
---Setting range---
1 to 27
291