M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1037
cmdtyp
Set the G code list and compensation type for programs.
1 : List1(for M)
2 : List1(for M)
3 : List2(for L)
4 : List3(for L)
5 : List4(for special L)
6 : List5(for special L)
7 : List6(for special L)
8 : List7(for special L)
9 : List8(for M)
(one compensation amount for one compensation No.)
10 : List8(for M)
(shape and wear compensation amounts for one compensation No.)
There are some items in the specifications that can be used or cannot be used according to the value set in
this parameter.
The file structure may also change depending on the compensation data type.
(Note) When this parameter is changed, the file system will be changed after the power is turned ON.
So always execute format.
The new format will be enabled after turning the power ON again.
Setting order
(1) cmdtyp changeover -> (2) Turn power ON again -> (3) Format -> (4) Turn power ON again
(Note) Compensation type III can be selected for M system by setting #1046.
#1073
I_Absm
Select the mode (absolute or incremental) at turning ON the power or reset.
0: Incremental setting
1: Absolute setting
#1074
l_Sync
Select the feedrate mode at turning ON the power or reset.
0: Asynchronous feed (feed per minute)
1: Synchronous feed (feed per revolution)
#1075
I_G00
Select the linear command mode at turning ON the power or reset.
0: Linear interpolation (G01 command state)
1: Positioning (G00 command state)
#1076
Abslnc
Select the command method for the absolute and incremental commands.
The absolute command/incremental command can be issued by using the absolute command address and
incremental command address for the same axis.
0: Use G command for the absolute and incremental commands.
1: Use axis name for the absolute and incremental commands.
(The axis name in "#1013 axname" will be the absolute command, "#1014 incax" will be the incremental
command.)
#1085
G00Drn
Select whether to apply dry run (feed at manual setting speed instead of command feedrate) to the G00 com-
mand.
0: Not apply to G00. (move at rapid traverse rate)
1: Apply to G00. (move at manual setting speed)
Command type
Type I (one compensation amount for one compensation No.)
Type II (shape and wear compensation amounts for one comp. No.)
Type III (shape and wear compensation amounts for one comp. No.)
Ditto
Ditto
Ditto
Ditto
Ditto
M2 form at type
Type I
M2 form at type
Type II
Initial absolute setting
Initial synchronous feed
Initial G00
ABS/INC address (for L system only)
G00 dry run