Mitsubishi Electric M800 Series Manual page 685

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#24023+40(n-1)
[M8]
Set the refresh device No. of the special relay (SB) to be automatically refreshed.
"n" represents the expansion slot No.(n=1 to 3)
(Note 1) When setting parameters in ALL.PRM with using the parameter input/output function, input the de-
vice No. of decimal digit.
(Example) When setting "X400" for the remote input (RX) refresh device No., input as follows;
#24014+40(n-1): "X" #24015+40(n-1): "1024"
(Note 2) When the refresh device name has been set, the refresh device No. will be "0".Confirm the refresh
device No. after changing the refresh device name.
When specifying a bit device, set the address in increments of 16 points.
The operation will not be guaranteed unless the address is set in increments of 16 points.
(Example) 1F0
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
M: 0 to 10239
L: 0 to 511
B: 0 to 1FFF
D: 0 to 2047
W: 0 to 1FFF
SB: 0 to 1FF
R: 8300 to 9799, 9800 to 9899
#24024+40(n-1)
[M8]
Set the refresh device name of the special relay (SW) to be automatically refreshed.
"n" represents the expansion slot No.(n=1 to 3)
(Example) SW
Set "0" when no setting is required.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
0,M,L,B,D,W,R,SW
IB-1501279-H
SLn SB dev No.
SLn SW dev name
668
Special relay (SB) refresh device No.
Special relay (SW) refresh device name

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents