16 Machine Parameters
#3009
ssift 1
Set the spindle speed for gear shifting with gear 00.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
#3010
ssift 2
Set the spindle speed for gear shifting with gear 01.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
#3011
ssift 3
Set the spindle speed for gear shifting with gear 10.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
#3012
ssift 4
Set the spindle speed for gear shifting with gear 11.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
#3013
stap 1
Set the speed which switches from 1st step to 2nd step in synchronous tapping multi-step acceleration/de-
celeration control when gear 00 is selected.
The inclination of linear acceleration/deceleration control for 1st step is determined by the ratio of
"stap1"(#3013) to "stapt1"(#3017).
When the inclination is not set after 2nd step or it is higher than that of 1st step, the acceleration/deceleration
control is executed with the same inclination as the 1st step for the rotation speed of "stap1" or higher.
---Setting range---
0 to 99999 (r/min)
#3014
stap 2
Set the speed which switches from 1st step to 2nd step in synchronous tapping multi-step acceleration/de-
celeration control when gear 01 is selected.
The inclination of linear acceleration/deceleration control for 1st step is determined by the ratio of
"stap2"(#3014) to "stapt2"(#3018).
When the inclination is not set after 2nd step or it is higher than that of 1st step, the acceleration/deceleration
control is executed with the same inclination as the 1st step for the rotation speed of "stap2" or higher.
---Setting range---
0 to 99999 (r/min)
#3015
stap 3
Set the speed which switches from 1st step to 2nd step in synchronous tapping multi-step acceleration/de-
celeration control when gear 10 is selected.
The inclination of linear acceleration/deceleration control for 1st step is determined by the ratio of
"stap3"(#3015) to "stapt3"(#3019).
When the inclination is not set after 2nd step or it is higher than that of 1st step, the acceleration/deceleration
control is executed with the same inclination as the 1st step for the rotation speed of "stap3" or higher.
---Setting range---
0 to 99999 (r/min)
IB-1501279-H
Shift rotation speed (Gear: 00)
Shift rotation speed (Gear: 01)
Shift rotation speed (Gear: 10)
Shift rotation speed (Gear: 11)
Synchronous tapping 1st step rotation speed (Gear: 00)
Synchronous tapping 1st step rotation speed (Gear: 01)
Synchronous tapping 1st step rotation speed (Gear: 10)