15 User Parameters
#8917

Auto backup day 3

[M8]
The automatic backup is executed at the first power ON of the NC in the period between the designated date
and the end of that month.
When "-1" is set to "Auto backup day 1", the automatic backup is executed every turning NC power ON.
When "0" is set to all on "Auto backup day 1" to "4", the automatic backup is not executed.
It is possible to specify the designated date up to 4 days for a month.
---Setting range---
-1 to 31
("-1" can be set only for Automatic backup day 1)
[C80]
Not used.
#8918

Auto backup day 4

[M8]
The automatic backup is executed at the first power ON of the NC in the period between the designated date
and the end of that month.
When "-1" is set to "Auto backup day 1", the automatic backup is executed every turning NC power ON.
When "0" is set to all on "Auto backup day 1" to "4", the automatic backup is not executed.
It is possible to specify the designated date up to 4 days for a month.
---Setting range---
-1 to 31
("-1" can be set only for Automatic backup day 1)
[C80]
Not used.
#8919

Auto backup device

[M8]
Select the automatic backup target device.
[M800W/M80W with Windows-based display]
0: DS
1: HD
2: Memory card
3: USB Memory
[M800S/M80 Series and E80]
[M800W/M80W with Windows-less display]
0: DS
2: Memory card
3: USB Memory
(Note) The setting range differs according to the model.
[C80]
Not used.