16 Machine Parameters
(PR)
#11062-
NoHistDevIn.1-5
11066
[C80]
Specify the PLC input signal (X) that is excluded from the PLC signal log.
Efficiency of the history analysis is improved by excluding the machine contact input/output signals or other
frequently switched signals from the signal log.
When "0" is set, the history exclusion PLC input signal is disabled.
Thus X0 cannot be excluded from the signal log.
---Setting range---
0000 to 1FFF
(PR)
#11067-
NoHistDevOut.1-5
11071
[C80]
Specify the PLC output signal (Y) that is excluded from the PLC signal log.
Efficiency of the history analysis is improved by excluding the machine contact input/output signals or other
frequently switched signals from the signal log.
When "0" is set, the history exclusion PLC output signal is disabled.
Thus Y0 cannot be excluded from the signal log.
---Setting range---
0000 to 1FFF
(PR)
#11080

HomeScreen display

[M8]
Select whether to display the home screen.
0: Not display
1: Display (display at power ON)
2: Display (not display at power ON)
[C80]
Not used.
(PR)
#11082

Lsys_change_Gtype

When switching the program format from M system to L system with program format switch command (G188)
or when switching G code guidance from M system to L system by the menu [Edit]-[Guide M/L], the G code
systems after switching follow the setting of this parameter.
0: L system G code system 2
1: L system G code system 3
2: L system G code system 4
3: L system G code system 5
4: L system G code system 6
5: L system G code system 7
#11086

rot_angle_dsp

Select the type of counter display (workpiece coordinate position, relative position and absolute position)
while #8116 is 0 (coordinate rotation by parameter is enabled).
0: Display the position relative to the orthogonal coordinate system.
1: Display the position relative to the coordinate system rotated through the coordinate rotation by param-
eter.
(with EXT [external workpiece coordinate offset] added during automatic operation)
2: Display the position relative to the coordinate system rotated through the coordinate rotation by param-
eter.
(with EXT [external workpiece coordinate offset] constantly added)
History exclusion PLC input signal 1 to 5
History exclusion PLC output signal 1 to 5
HomeScreen display
L system G code system after program format switch
(for M system only)
Counter display during coordinate rotation