M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1562
3Dremc
The remaining command display during 3D coordinate conversion is switched to the workpiece coordinate
system or G68 program coordinate system.
0: Workpiece coordinate system
1: G68 program coordinate system
#1563
3Dcdrc
The coordinate system of the workpiece/skip coordinate read value in the 3D coordinate conversion modal
is switched.
0: G68 program coordinate system
1: Workpiece (local) coordinate system
#1564
3Dspd
Set the rapid traverse rate for the hole drilling cycle during 3D coordinate conversion.
0: The cutting feed clamp speed is used.
Other than 0: The set speed is used.
Note that if the rapid traverse rate is exceeded, the speed will be clamped at the rapid traverse rate.
---Setting range---
0 to 1000000mm/min
#1565
helgear
Set the base axis for helix angle calculation in helical machining. When no setting, Z axis will be used.
---Setting range---
Axis name such as X, Y, Z, U, V, W, A, B, and C
#1566
3DSelctDrillaxMode
Switch the rapid traverse mode in non-drilling blocks among a drilling cycle to the cutting feed mode during
3-dimensional coordinate conversion.
0: Rapid traverse mode. The speed follows the setting of "#2001 rapid".
1: Cutting feed mode. The speed follows the setting of "#1564 3Dspd".
#1568
SfiltG1
Set the filter time constant for smoothly changing the acceleration rate for the cutting feed acceleration/de-
celeration in pre-interpolation acceleration/deceleration.
- Notch frequency Hz
Displays the notch frequency (Hz) for the S-pattern filter set in "#1568 SfiltG1" (G01 soft acceleration/decel-
eration filter).
---Setting range---
0 to 200 (ms)
#1569
SfiltG0
Set the filter time constant for smoothly changing the acceleration rate for the rapid traverse acceleration/
deceleration in pre-interpolation acceleration/deceleration.
---Setting range---
0 to 200 (ms)
#1570
Sfilt2
Set the filter time constant for smoothly changing the acceleration rate in pre-interpolation acceleration/de-
celeration.
This will be disabled when "0" or "1" is set.
- Notch frequency Hz
Displays the notch frequency (Hz) for the S-shape filter set in "#1570 Sfilt2" (Soft acceleration/deceleration
filter 2).
---Setting range---
0 to 200 (ms)
Switch remaining command display during 3D coordi-
nate conversion
Switch coordinate reading during 3D coordinate con-
version
Hole drilling speed during 3D coordinate conversion
Helical machining base axis
Switch drill axis's mode from rapid traverse during 3D
coordinate conversion
G01 soft acceleration/deceleration filter
G00 soft acceleration/deceleration filter
Soft acceleration/deceleration filter 2