Aux07 - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1223

aux07

bit1: Deceleration check method 2
Select the deceleration check method in G1+G9.
0: Command deceleration check in G1+G9
1: In-position check in G1+G9
The deceleration check is not performed for the commands except G1+G9.
When "#1306 InpsTyp deceleration check specification type" is set to "1" (Deceleration check specification
type 2), this parameter will be invalid.
bit2: Synchronous tap R-point in-position check
Select whether to enable the synchronous tap I-point -> R-point in-position check.
0: Disable
1: Enable
(Note) This parameter is valid only when "1" (Enable in-position check) is set for "#1223 aux07/bit3 Synchro-
nous tap in-position check improvement".
bit3: Synchronous tap in-position check improvement
Select whether to enable the synchronous tap in-position check improvement.
0: Disable
1: Enable
Related parameters:
#1223/bit2 Synchronous tap R-point in-position check
#1223/bit4 Synchronous tap hole bottom in-position check
#1223/bit5 Synchronous tap R-point in-position check 2
bit4: Synchronous tap hole bottom in-position check
Select whether to enable the synchronous tap hole bottom in-position check.
0: Disable
1: Enable
(Note) This parameter is valid only when "1" (Enable in-position check) is set for "#1223 aux07/bit3 Synchro-
nous tap in-position check improvement".
bit5: Synchronous tap R-point in-position check 2
Select whether to enable the synchronous tap R-point in-position check.
0: Disable
1: Enable
(Note) This parameter is valid only when "1" (Enable in-position check) is set for "#1223 aux07/bit3 Synchro-
nous tap in-position check improvement".
bit6: Cancel synchronous tap (, S) return
0: Retain the spindle speed (, S) in synchronous tap return
1: Cancel the spindle speed (, S) in synchronous tap return with G80
bit7: Synchronous tap method
Select the synchronous tapping method.
0: Synchronous tapping with multi-step acceleration and rapid return
1: Conventional type synchronous tapping
IB-1501279-H