M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#9739

Host 2 Wrd pos: cmnt

[M8]
Set the comment (date, time, etc.) display position (nth word from left) of the list displayed when the ftp com-
mand "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---
0 to 100
0: Default value
[C80]
Not used.
#9740

Host 2 Wrd num: cmnt

[M8]
Set the number of words to be displayed as a comment.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---
0 to 100
0: Default value
[C80]
Not used.
#9741

Host 2 no total siz

[M8]
Set whether to display the total number of characters registered in the machining programs of host1 when
displaying the file list.
If there are many files in the directory to be referred to, the list can be updated quickly by setting "1".
0: Display
1: Not display
[C80]
Not used.
#9751

Host3 host name

[M8]
Set the host computer name.
This parameter allows the NC to easily recognize the host computer on the network. Set the host computer's
name (name registered in C:\windows\hosts) or the IP address.
<Setting example>
For host name: mspc160
For IP address: 150.40.0.111
(Note) Set the host computer's TCP/IP address if communication is not carried out correctly.
---Setting range---
15 characters (alphanumeric) or less
[C80]
Not used.