M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#13196
SP196 LMNL
Set the base speed of the standard output to be displayed as 100% in load meter.
When "0" is set, the base speed of the short-time rated output will be applied.
It is not available for MDS-EJ-SP Series.
---Setting range---
0 to 32767 (r/min)
#13197-
SP197-SP198
13198
Not used. Set to "0".
#13199
SP199 RTGM
In case that machine resonance is induced when mounting a workpiece, the speed loop gain is switched au-
tomatically in response to inertia by setting the speed loop gain and workpiece inertia multiplier in advance.
The speed loop gain SP199(RTGM) changes in response to the estimated inertia ratio SP200(RTJX) based
on the speed loop gain SP005(VGN1) and the inertia multiplier SP037(JL) which were adjusted when no
workpiece was mounted.
When SP199 is set to "0", the adaptation of the speed loop gain will be disabled.
Speed control gain multiplier [%]
RTGM
(SP199)
VGN1
(SP005)
Related parameters: SP005, SP037, SP200
---Setting range---
0 to 5000 (%)
IB-1501279-H
Base speed for load meter standard output (Low-speed
coil)
Real-time tuning: maximum adaptive gain multiplier