M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
16.4 Axis Specifications Parameters
#2001
rapid
Set the rapid traverse feedrate for each axis.
(Note) The maximum value to be set depends on the machine specifications.
---Setting range---
1 to 1000000 (mm/min)
#2002
clamp
Set the maximum cutting feedrate for each axis.
Even if the feedrate in G01 exceeds this value, the clamp will be applied at this feedrate.
---Setting range---
1 to 1000000 (mm/min)
IB-1501279-H
Rapid traverse rate
Cutting feedrate for clamp function
468