M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#13128
SP128 DA2MPY
Set the output scale in increments of 1/100.
When "0" is set, the scale is the same as when "100" is set.
---Setting range---
-32768 to 32767 (1/100-fold)
(PR)
#13129-
SP129-SP141
13141
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and specifications,
so normally set the value given in the spindle parameter list.
(PR)
#13142
SP142
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and specifications,
so normally set the value given in the spindle parameter list.
For IPM spindle motor
This parameter is used in initial magnetic pole detection of IPM spindle motor.
(1) Pulse application time: Set it in [μs] unit.(0 < application time < 350)
(2) Pulse application coil: To select a low-speed coil, add 1000 to the pulse application time.
(3) Polarity of estimated magnetic pole: When it is set to the reverse polarity, add "-" to the total of (1) and (2).
E.g.: When performing 333μs pulse-applied magnetic pole estimation in a low-speed coil and selecting the
reverse polarity for the estimated polarity
SP142 = -(333+1000) = -1333
(PR)
#13143-
SP143-SP160
13160
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and specifications,
so normally set the value given in the spindle parameter list.
(PR)
#13161-
SP161-SP192
13192
Set the unique constants for the spindle motor. (Low-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and specifications,
so normally set the value given in the spindle parameter list.
#13193
SP193 LMR
Set the standard output to be displayed as 100% in load meter using the short-time rated output ratio.
To display the continuous rated output as 100%, set as follows.
Continuous rated output/Short-time rated output × 100
When "0" is set, normal display will be applied.
It is not available for MDS-EJ-SP Series.
---Setting range---
0 to 100 (%)
#13194
SP194 LMN
Set the base speed of the standard output to be displayed as 100% in load meter.
When "0" is set, the base speed of the short-time rated output will be applied.
It is not available for MDS-EJ-SP Series.
---Setting range---
0 to 32767 (r/min)
#13195
SP195 LMRL
Set the standard output to be displayed as 100% in load meter using the short-time rated output ratio.
To display the continuous rated output as 100%, set as follows.
Continuous rated output/Short-time rated output × 100
When "0" is set, normal display will be applied.
It is not available for MDS-EJ-SP Series.
---Setting range---
0 to 100 (%)
D/A output ch2 output scale
Change magnification for load meter standard output
(High-speed coil)
Base speed for load meter standard output (High-speed
coil)
Change magnification for load meter standard output
(Low-speed coil)
609