16 Machine Parameters
#11030

Man tap sync cancl

Select whether handle feed of the tapping axis in manual synchronous tappingsynchronizes with the spindle
or not.
0: Synchronize with the spindle
1: Not synchronize with the spindle
(PR)
#11031

Cursor pos search

Select the cursor position searching method.
0: Disable
1: Pressing the INPUT key in [Monitr] - [Edit] menu starts the operation search for the block with the cursor.
2: Turning ON/OFF the "Edit/Search" signal in [Monitr] - [Edit] menu starts the operation search for the
block with the cursor.
3: Turning ON/OFF the "Edit/Search" signal in [Monitr] - [Edit] menu starts the operation search for the
block with the cursor. Pressing the reset key shows the top of the program on the [Edit/Search] window.
(PR)
#11032

Menu sel para lkof

Select whether to enable the setting of the "menu selection parameters" (#10501 to #10530, #10551 to
#10580, and #10601 to #10630), with which the order of main menus on Monitor, Setup and Edit screens
can be rearranged. And also select who is allowed to do this setting.
0: Disable
1: Enable (machine tool builder password is required)
2: Enable (users are allowed to set)
(PR)
#11033

skipB_no_sens

Select the contact of the sensor which you wish to set as unconnected, when the skip signal is set to contact
B.
Set "1" for the contact to be unconnected.
bit0: Skip input 1
bit1: Skip input 2
bit2: Skip input 3
bit3: Skip input 4
bit4: Skip input 5
bit5: Skip input 6
bit6: Skip input 7
bit7: Skip input 8
(Note 1) This parameter is enabled when "#1258 set30/bit0" is set to "1".
(Note 2) This parameter is independent of PLC skip.
---Setting range---
00000000 to 11111111 (Binary)
#11034
G12AddrCheckType
Select the type of command address to check in circular cutting.
0: Regard command addresses other than D, F, I as illegal.
1: Regard the command address H as illegal. And commands other than D,F,I and M,S,T,B are disabled.
#11035
Sys. change limit
This restricts switching the part systems displayed on screen.
0: Not restrict
1: Disable the part system switching by pressing [$<->$] key on touch panel.
2: Disable the part system switching by display switch signals(Y730 to Y733).
IB-1501279-H
Synchronization cancel in manual synchronous tap-
ping
Cursor position search
Validate menu selection parameter setting
Unconnected sensor selection when skip is set to con-
tact B
Command address type to check in circular cutting