Validate F1 Digit; Sub-Pro Interrupt; Fine Thread Cut E; Radius Comp Type B (M System) / Nose R Comp Type B (L System) - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#8145

Validate F1 digit

Select whether to execute the F command with a 1-digit code command or with a direct numerical command.
(The same value as "#1079 F1digt" will be reflected. When either setting changes, the other will change ac-
cordingly.)
0: Direct numerical command (command feedrate during feed per minute or rotation)
1: 1-digit code command (with the feedrate specified by the parameters "#1185 spd_F1" to "#1189 sp-
d_F5")
#8155

Sub-pro interrupt

Select the method for the user macro interrupt.
(The same value as "#1229 set01/bit0" will be reflected. When either setting changes, the other will change
accordingly.)
0: The user macro interrupt of macro type
1: The user macro interrupt of sub-program type
#8156

Fine thread cut E

Select the address E type when cutting an inch screw.
(The same value as "#1229 set01/bit1" will be reflected. When either setting changes, the other will change
accordingly.)
0: Specify the number of threads per inch for inch screw cutting.
1: Specify the precision lead for inch screw cutting.
#8157

Radius comp type B (M system) / Nose R comp type B (L system)

For M system
Select the method of the arithmetic processing for the intersection point when the start-up or cancel com-
mands are operated during radius compensation.
(The same value as "#1229 set01/bit2" will be reflected. When either setting changes, the other will change
accordingly.)
0: The processing does not handle the start-up or cancel command block: handle the offset vector in the
direction vertical to that of the command instead.
1: The processing is executed for the intersection point between the command block and the next block.
For L system
Select the method of the arithmetic processing for the intersection point when the start-up or cancel com-
mands are operated during nose R or radius compensation.
(The same value as "#1229 set01/bit2" will be reflected. When either setting changes, the other will change
accordingly.)
0: The processing does not handle the start-up or cancel command block: handle the offset vector in the
direction vertical to that of the command instead.
1: The processing is executed for the intersection point between the command block and the next block.
#8158
Init const sur spd
Select the initial state after power-ON.
(The same value as "#1229 set01/bit3" will be reflected. When either setting changes, the other will change
accordingly.)
0: Constant surface speed control cancel mode.
1: Constant surface speed control mode.
#8159
Synchronous tap
Select whether to use the floating tap chuck in G74 and G84 tap cycles.
(The same value as "#1229 set01/bit4" will be reflected. When either setting changes, the other will change
accordingly.)
0: With a floating tapping chuck
1: Without a floating tapping chuck
#8160
Start point alarm
Select an operation when the operation start point cannot be found while moving to the next block of G117.
(The same value as "#1229 set01/bit5" will be reflected. When either setting changes, the other will change
accordingly.)
0: The auxiliary function is enabled after the block for the movement has finished.
1: The program error (P33) occurs.
IB-1501279-H
226

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents