Mitsubishi Electric M800 Series Manual page 494

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#2080
chwid
Set the tolerance between the commanded stroke and actual stroke.
Compensation will be applied during chopping so that the result of [command width - maximum stroke of top
or bottom dead point/ 2] will be within this tolerance.
---Setting range---
0 to 10.000 (mm)
#2081
chclsp
Set the clamp speed in chopping operation.
When "0" is set, the clamp speed will be determined by "#2002 clamp".
---Setting range---
0 to 60000 (mm/min)
#2082
a_rstax
Set the No. for each axis in order from the 1st automatically returning axis to the restart position.
When "0" is set, the axis will not return.
Note that when "0" is set for all axes, all of the axes will return simultaneously.
(Note) On the absolute position system, when performing the restart search just after power ON, and when
the axis that is the order 0 is moved by the follow-up, an operation error(M01 0128) may occur.
---Setting range---
0 to 16
#2084
G60_ax
Select how to operate the unidirectional positioning when the positioning command (G00) is issued.
0: Carry out unidirectional positioning according to the command and modal.
1: Carry out unidirectional positioning regardless of the command and modal.
Set "1" for the axis to carry out the unidirectional positioning at every positioning command, regardless of
whether the unidirectional positioning command and modal are issued.
<Related parameters>
"#8209 G60 SHIFT" and "#2076 index_x"
#2086
exdcax
Set the maximum feed rate for each axis when the external deceleration signal is ON.
This parameter is enabled when "#1239 set11/bit6 (External deceleration axis compliance valid)" is set to "1".
---Setting range---
0 to 1000000 (mm/min)
#2087
syncnt
Set the polarity of synchronous axis with respect to basic axis to the bit corresponding to each axis.
0: Polarity with respect to basic axis is positive
1: Polarity with respect to basic axis is negative
---Setting range---
0 to FF (hexadecimal)
#2088
bsax_sy
Set the basic axis for synchronous control with the 2nd axis name (axname2).A numerical character cannot
be set as the 1st character.
---Setting range---
1st character:A to Z
2nd character:A to Z, 1 to 9
Bottom dead center position width
Maximum chopping speed
Restart position return order
Unidirectional positioning operation selection
External deceleration speed
Synchronization/super-imposition control setting for
each axis
Reference axis for synchronous control
477