M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters

16.13 PLC Integrated Timer

#17000-
ST0 - ST63
17063
Set the time for the integrated timer used with the PLC program (ladder).
(Note1) This setting value is valid when bit selection parameter "#6449/bit0" is set to "0".
(Note2) Setting the timer setting value from the setting and display unit
The timer T setting value can be set with the following two methods.
- Method to validate the setting value (Kn) programmed with the sequence program (fixed integrated timer)
- Method to validate the setting value set from the setting and display unit (variable integrated timer)
(Note3) As described bellow, the setting method of timer ST and No. of points can be set with the bit selection
parameters (#6453/bit5 to bit7).
- #6453/bit5=0, bit6=0, bit7=0
No. of points: 0
Range: None
Setting method: All fixed integrated timers
- #6453/bit5=1, bit6=0, bit7=0
No. of points: 20
Range: #17000 to #17019
Setting method: Set above range with variable integrated timer.
- #6453/bit5=0, bit6=1, bit7=0
No. of points: 40
Range: #17000 to #17039
Setting method: Set above range with variable integrated timer.
- #6453/bit5=1, bit6=1, bit7=0
No. of points: All points
Range: #17000 to #17063
Setting method: All variable integrated timers
---Setting range---
0 to 32767( x 100ms)
IB-1501279-H
PLC integrated timer <100ms INC.>
628