16 Machine Parameters
#3016
stap 4
Set the speed which switches from 1st step to 2nd step in synchronous tapping multi-step acceleration/de-
celeration control when gear 11 is selected.
The inclination of linear acceleration/deceleration control for 1st step is determined by the ratio of
"stap4"(#3016) to "stapt4"(#3020).
When the inclination is not set after 2nd step or it is higher than that of 1st step, the acceleration/deceleration
control is executed with the same inclination as the 1st step for the rotation speed of "stap4" or higher.
---Setting range---
0 to 99999 (r/min)
#3017
stapt 1
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when gear 00
is selected. (linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)
#3018
stapt 2
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when gear 01
is selected. (linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)
#3019
stapt 3
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when gear 10
is selected. (linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)
Synchronous tapping 1st step rotation speed (Gear: 11)
Synchronous tapping 1st step acceleration/decelera-
tion time constant (Gear: 00)
Synchronous tapping 1st step acceleration/decelera-
tion time constant (Gear: 01)
Synchronous tapping 1st step acceleration/decelera-
tion time constant (Gear: 10)