M800/M80/E80/C80 Series Alarm/Parameter Manual
5 System Alarms (Z)
Z36

EcoMonitorLight comm. error

Details
An error has occurred in the communication with EcoMonitorLight.
Remedy
Make sure that the CNC has the same communication settings (station No.,baud rate, parity and stop bit) as
the EcoMonitorLight in error.
Make sure that there are no problems with the serial cable connected to the EcoMonitorLight.
Make sure to place the serial cable in a low-noise environment.
Z37

EcoMonitorLight qty discrepant

Details
The number of EcoMonitorLight units connected is inconsistent with the setting of the parameter #11061.
Remedy
Make sure that the value set in the parameter #11061 coincides with the number of EcoMonitorLight units con-
nected to the CNC.
Also make sure all the EcoMonitorLight units connected are powered ON and the station No. is not duplicated.
Z38

Insulation deterioration wrn

Details
The motor insulation has been deteriorated.
0001: Motor insulation deterioration: Caution
0002: Motor insulation deterioration: Replacement required
0003: Motor insulation deterioration: Relay welding detected
Remedy
0001: The insulation resistance value of the motor has dropped.
Contact the service center.
0002: The insulation resistance value of the motor is less than or equal to the reference value.
Contact the service center.
When measuring the insulation resistance of the motor and the measured resistance value is less than
or equal to the specified value, the motor may be damaged.
0003: The drive unit may be damaged.
Contact the service center.
Z39

E-mail send error

Details
E-mail sending with the email notification to operator function failed.
Remedy
Check the e-mail environment setting.
Check the registered e-mail address.
Set "0" in "#8134 E-mail send disabled".
Z40
Format mismatch
Details
"#1052 MemVal (No. of common variables shared in part system designation)", formatted at "0", was set to "1".
Remedy
Reset "#1052 MemVal (No. of common variables shared in part system designation)" to "0" or format and
restart.
Z49
RIO watchdog error
Details
An error has occurred in the remote I/O unit.
Remedy
Turn the power ON again.
If this error remains active after the power ON, replace the remote I/O unit.