16 Machine Parameters
#2074
H/W_OT+
Under the standard specifications, the OT (+) signal is assigned to a fixed device. Set the input device in this
parameter when it is desired to assign the OT (+) signal to a position other than the fixed device.
(Note1) This parameter is enabled in the following conditions.
NC axis: When "#1226 aux10/bit5" is set to "1".
PLC axis: When "#1246 set18/bit7" is set to "1".
(Note 2) When this parameter is valid, do not set the existing device number. If the existing device number
is set, an emergency stop will occur. However, no device number check will be performed for an axis to
which the "OT ignored" signal is input.
---Setting range---
0000 to 02FF (HEX)
#2075
H/W_OT-
Under the standard specifications, the OT (-) signal is assigned to a fixed device. Set the input device in this
parameter when it is desired to assign the OT (-) signal to a position other than the fixed device.
(Note1) This parameter is enabled in the following conditions.
NC axis: When "#1226 aux10/bit5" is set to "1".
PLC axis: When "#1246 set18/bit7" is set to "1".
(Note 2) When this parameter is valid, do not set the existing device number. If the existing device number
is set, an emergency stop will occur. However, no device number check will be performed for an axis to
which the "OT ignored" signal is input.
---Setting range---
0000 to 02FF (HEX)
#2076
index_x
Select whether the axis is a normal axis or an index table indexing axis.
0: Normal axis
1: Index table indexing axis
(Note) This parameter is valid only for the NC axis. The parameter is invalid if set for the PLC axis.
#2077
G0inps
Set the in-position width for G0.
Between SV024 and this parameter, the parameter with a larger value will be applied.
When "0" is set, this parameter will be invalid: only SV024 will be available.
When "#1205 G0dbcc" is "1", SV024 is used as the G0 in-position width.
---Setting range---
0.000 to 99.999 (mm)
#2078
G1inps
Set the in-position width for G1.
Between SV024 and this parameter, the parameter with a larger value will be applied.
When "0" is set, this parameter will be invalid: only SV024 will be available.
---Setting range---
0.000 to 99.999 (mm)
(PR)
#2079
chcomp
Set the coefficient to be applied to the compensation amount for the insufficient amount caused by servo de-
lay during chopping.
---Setting range---
0 to 10 (standard value: 8)
IB-1501279-H
H/W OT+ Random assignment device
H/W OT- Random assignment device
Index table indexing axis
G0 in-position width
G1 in-position width
Chopping compensation coefficient
476

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents