M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#1126

PB_G90

Select the method to command the playback travel amount in the playback editing.
0: Incremental value
1: Absolute value
#1128

RstVCI

Select how to handle the common variables when resetting.
0: Common variables won't change after resetting.
1: Common variables will be cleared #100 to #199 by resetting.
#1129

PwrVCl

Select how to handle the common variables when the power is turned ON.
0: The common variables are in the same state as before turning the power OFF.
1: Common variables will be cleared #100 to #199 when the power is turned ON.
#1302

AutoRP

Select the method to move to the restart position when restarting the program.
0: Move the system manually to the restart position and then restart the program.
1: The system automatically moves to the restart position at the first activation after the program restarts.
#8101
MACRO SINGLE
Select how to control the blocks where the user macro command continues.
0: Do not stop while macro blocks continue.
1: Stop every block during signal block operation.
#8102
COLL. ALM OFF
Select the interference (bite) control to the workpiece from the tool diameter during tool radius compensation
and nose R compensation.
0: An alarm will be output and operation stops when an interference is judged.
1: Changes the path to avoid interference.
#8103
COLL. CHK OFF
Select the interference (bite) control to the workpiece from the tool diameter during tool radius compensation
and nose R compensation.
0: Performs interference check.
1: Does not perform interference check.
#8105
EDIT LOCK B
Select the edit lock for program Nos. 8000 to 9999 in the memory.
0: Enable the editing.
1: Prohibit the editing of above programs.
When "1" is set, the file cannot be opened.
#8106
G46 NO REV-ERR (for L system only)
Select the control for the compensation direction reversal in G46 (nose R compensation).
0: An alarm will be output and operation will stop when the compensation direction is reversed (G41 ->
G42' G42 -> G41).
1: An alarm won't occur when the compensation direction is reversed, and the current compensation direc-
tion will be maintained.
#8107
R COMPENSATION
Select whether to move to the inside because of a delay in servo response to a command during arc cutting
mode.
0: Move to the inside, making the arc smaller than the command value.
1: Compensate the movement to the inside.
Playback G90
Clear variables by resetting
Clear variables by power-ON
Automatic return by program restart