Mitsubishi Electric M800 Series Manual page 587

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#3168
StlTrqSPSV(PwrCal)
Specify the stall torque of spindle-mode servo motor.
This value is used for calculating the power consumption of the spindle-mode servo motor.
---Setting range---
0.000 to 1000.000 (Nm)
#3169
rotspzsp
Set the motor rotation speed to which the zero speed detection is executed. When the motor speed goes
below the set speed, the zero speed detection turns ON.
The standard setting value is "50".
When the setting value is "0", it is on the standard setting value.
---Setting range---
0 to 1000(r/min)
#3170
rotspsdts
Set the motor speed to which the speed detection is executed. When the motor speed goes below the set
speed, the speed detection turns ON.
The standard setting value is 10% of the "#3001 slimt1" setting value.
When the setting value is "0", it is on the standard setting value.
---Setting range---
0 to 32767(r/min)
(PR)
#3171
CrshStpSel
Select spindle stop method at collision detection
Select the spindle stop method when a collision is detected with an axis whose setting of "#2634 Select stop
method at collision detection" is 1.
bit0: Spindle decelerates to stop if the collision was detected in $1
bit1: Spindle decelerates to stop if the collision was detected in $2
bit2: Spindle decelerates to stop if the collision was detected in $3
bit3: Spindle decelerates to stop if the collision was detected in $4
If 0 is set, spindle does not stop when a collision is detected in any part system.
It is possible to set more than one part system.
---Setting range---
0 to F (HEX)
(PR)
#3192
LdMeter thresholdY
Specify the spindle load (%) at which the loadmeter displays a caution sign (yellow).
If spindle load exceeds the specified value, the loadmeter displays a caution (yellow).
If you wish to avoid showing the caution (yellow), set this parameter to be the same as #3193 LdMeter thresh-
oldR.
When "0" is set, the value becomes 100% (default).
---Setting range---
0 to 300 (%)
(PR)
#3193
LdMeter thresholdR
Specify the spindle load (%) at which the loadmeter displays a warning sign (red).
If spindle load exceeds the specified value, the loadmeter displays a warning (red).
If you wish to avoid showing the warning (red), set this parameter to be the same as #3194 LdMeter load max.
When "0" is set, the value becomes 150% (default).
---Setting range---
0 to 300 (%)
IB-1501279-H
Stall torque of spindle-mode servo motor for power
computation
Spindle-mode rotary axis Motor zero speed (For spin-
dle-mode rotary axis only)
Spindle-mode rotary axis Speed detection setting value
(For spindle-mode rotary axis only)
Select spindle stop method at collision detection
Loadmeter: Caution (Yellow) threshold
Loadmeter: Warning (Red) threshold
570

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents