M800/M80/E80/C80 Series Alarm/Parameter Manual
2 Stop Codes (T)
T04

Collation stop

Details
Collation stop occurred.
Remedy
Execute the automatic start to resume the automatic operation.
T10

Fin wait

Details
The following Nos. are shown during the operation of the corresponding completion wait factor. The numbers
will disappear when the operation is completed.
The completion wait factor is indicated with four digits (in hexadecimal).
Display format of completion wait factor
0__ __ __
(a)(b)(c)
Each of the hexadecimal numbers (a), (b) and (c) indicates the following details.
(a)
bit0: In dwell execution
bit3: Unclamp signal wait (Note 1)
(b)
bit0: Waiting for spindle position to be looped
bit3: Door open (Note 2)
(c)
bit0: Waiting for MSTB completion
bit1: Waiting for rapid traverse deceleration
bit2: Waiting for cutting speed deceleration
bit3: Waiting for spindle orientation completion
(Note 1) For type A (#1282 ext18/bit3 = 0)
Waiting for turning ON or OFF of the unclamp finish signal for the index table indexing.
For type B (#1282 ext18/bit3 = 1)
Waiting for turning ON of the unclamp finish signal for the index table indexing.
Waiting for turning ON of the clamp finish signal for the index table indexing.
(*) The complete standby status is established when the unclamp finish and clamp finish signals are
both turned ON. Set the clamp finish signal to OFF after performing required process with the PLC.
(Note 2) This shows the door open state caused by the door interlock function.
T11
Fin wait
Details
The following Nos. are shown during the operation of the corresponding completion wait factor. The numbers
will disappear when the operation is completed.
The completion wait factor is indicated with four digits (in hexadecimal).
Display format of completion wait factor
0__ __ __
(a)(b)(c)
Each of the hexadecimal numbers (a), (b) and (c) indicates the following details.
(b)
bit0:Operation alarm display being postponed
Remedy
The parameter "#1342 AlmDly" may be able to postpone displaying a part of an operation alarm, depend-
ing on the setting.
This stop code will remain displayed while any alarm is being postponed.
And it will disappear if the postponed alarm is displayed or canceled.
IB-1501279-H