Var Protect Top1; Var Protect Btm1; Var Protect Top2; Var Protect Btm2 - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#12111

Var protect Top1

Specify the head of the common variables which are protected from setting operation.
(Note 1) If #12111 or #12112 is 0 or is greater than the bottom No. (#12112), this setting is disabled.
(Note 2) For the common variables shared by part systems, the protection takes effect in a part system set
by this parameter.
(Note 3) It is possible to set an unspecified variable, but the protection covers the specified variables only.
---Setting range---
0: Disabled
100 to 199, 400 to 999
(PR)
#12112

Var protect Btm1

Specify the end of the common variables which are protected from setting operation.
(Note 1) If #12111 or #12112 is 0 or is smaller than the top No. (#12111), this setting is disabled.
(Note 2) For the common variables shared by part systems, the protection takes effect in a part system set
by this parameter.
(Note 3) It is possible to set an unspecified variable, but the protection covers the specified variables only.
---Setting range---
0: Disabled
100 to 199, 400 to 999
(PR)
#12113

Var protect Top2

Specify the head of the common variables which are protected from setting operation.
(Note 1) If #12113 or #12114 is 0 or is greater than the bottom No. (#12114), this setting is disabled.
(Note 2) For the common variables shared by part systems, the protection takes effect in a part system set
by this parameter.
(Note 3) It is possible to set an unspecified variable, but the protection covers the specified variables only.
---Setting range---
0: Disabled
100 to 199, 400 to 999
(PR)
#12114

Var protect Btm2

Specify the end of the common variables which are protected from setting operation.
(Note 1) If #12113 or #12114 is 0 or is smaller than the top No. (#12113), this setting is disabled.
(Note 2) For the common variables shared by part systems, the protection takes effect in a part system set
by this parameter.
(Note 3) It is possible to set an unspecified variable, but the protection covers the specified variables only.
---Setting range---
0: Disabled
100 to 199, 400 to 999
#12121
REM Mcr No
[M8]
Specify the name of macro program for the rotation center error measurement.
The macro program name is input at initialization of rotation center error measurement macro.
If 0 is set, the macro program for the measurement is not input to the part system.
The macro program is used for execution of the measurement.
---Setting range---
0, 9000 to 9099, 9300 to 9999, 100010000 to 100018999, 100030000 to 199999998
IB-1501279-H
Common variable setting protection - Top variable No.
(1st group)
Common variable setting protection - Bottom variable
No. (1st group)
Common variable setting protection - Top variable No.
(2nd group)
Common variable setting protection - Bottom variable
No. (2nd group)
Macro No. for rotation center error measurement
372