16 Machine Parameters
(PR)
#1300
ext36
bit0: Multiple spindle control II
Select multiple spindle control I or II.
0: Multiple spindle control I (L system only)
1: Multiple spindle control II (select from ladder)
bit1: Spindle control for each part system
[M8]
Select whether to set spindle control command (S code/G96/G92) to be common in the part systems or to
be separated by each part system when multiple spindle control II is enabled (#1300 ext36/bit0 = 1).
0: Common in the part systems
1: Separated by each part system
[C80]
Not used.
bit2: Part system-based spindle clamp speed management
Select how to manage the spindle clamp speed data.
0: Manage the data of all part systems collectively
1: Manage the data of each part system individually
bit3: Spindle command rotation speed input timing selection
[M8]
When multiple-spindle control II is enabled (#1300 ext36/bit0 = 1), switch the timing to update the spindle
command rotation speed input when performing the spindle selection(SWS) or spindle command selec-
tion(SLSP) with M command given in the same block as S command.
0: S command updates the spindle command rotation speed input for the spindle which is before the selec-
tion by the spindle selection(SWS) or spindle command selection(SLSP).
1: S command updates the spindle command rotation speed input for the spindle which is after the selection
by the spindle selection(SWS) or spindle command selection(SLSP).
[C80]
Not used.
bit7: Spindle synchronization command method
Select the spindle synchronization command method.
0: Spindle synchronization with PLC I/F
1: Spindle synchronization with machining program
#1301
nrfchk
Select the high-speed check method of the origin neighboring signal.
0: Do not check positions near the origin at high speeds.
(Conventional specifications)
1: Check positions near the origin at high speeds using command machine positions.
2: Check positions near the origin at high speeds using detector feedback positions.
#1302
AutoRP
Select the method to move to the restart position when restarting the program.
0: Move the system manually to the restart position and then restart the program.
1: The system automatically moves to the restart position at the first activation after the program restarts.
(PR)
#1303
V1comN
Set the number of common variables, common for part systems, starting from address #100.
This is valid only when "#1052 MemVal" is set to "1".
---Setting range---
0 to 100
IB-1501279-H
Near reference position check method
Automatic return by program restart
No. of #100 address part system common variables
432