16 Machine Parameters
#12863
aux_stpos15
Set the station 15 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12864
aux_stpos16
Set the station 16 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12865
aux_stpos17
Set the station 17 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12866
aux_stpos18
Set the station 18 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12867
aux_stpos19
Set the station 19 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12868
aux_stpos20
Set the station 20 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12870
aux_PSWcheck
Select the criterion for the output of position switches 1 to 15.
bit0 to E correspond to position switches 1 to 15.
0: Judged by the machine position of the command system.
1: Judged by the machine FB position (actual position).
(Note) The bits that are not explained here must be set to "0".
#12871
aux_PSW1dog1
Set "PSW1 area setting" 1 and 2 to specify the area where the position switch 1 will turn ON when the ma-
chine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position switch op-
eration.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
IB-1501279-H
Station 15 coordinate
Station 16 coordinate
Station 17 coordinate
Station 18 coordinate
Station 19 coordinate
Station 20 coordinate
PSW detection method
PSW1 area setting 1