16 Machine Parameters
#7742+10(n-25)
[C80]
"n" represents the posistion switch No.(n=25 to 32)
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to the PLC.
For the device No., refer to the PLC Interface Manual.
---Setting range---
-99999.999 to 99999.999 (mm)
#7743+10(n-25)
[C80]
"n" represents the posistion switch No.(n=25 to 32)
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to the PLC.
For the device No., refer to the PLC Interface Manual.
---Setting range---
-99999.999 to 99999.999 (mm)
#7744+10(n-25)
[C80]
"n" represents the posistion switch No.(n=25 to 32)
When position switch area checking at high speed is selected, specify the mode of area checking, i.e., wheth-
er to use the command type machine position or detector feedback position, for each position switch.
0: Use the command type machine position as the machine position for position switch area checking.
1: Use the detector feedback position as the machine position for position switch area checking.
IB-1501279-H
PSWn dog1
PSWn dog2
PSWn check
644
Imaginary dog position 1
Imaginary dog position 2
Selection of area check method